Paint Shop and Powder-Coating Line CCTV Specification: Pixels per Metre, Lens, Heat, Ex Zones and Storage (India)
A one-booth, one-oven paint line needs about 6 cameras. Five sit outside the classified area at 125 px/m (IEC 62676-4:2014 Recognise, checked 15 Oct 2026). Only a camera inside the booth or a classified mixing room must be Ex-certified. A typical powder cures at 180–210 °C; the bullet cameras below are rated to +60 °C.
Last checked: 15 Oct 2026. The line layout is a worked assumption; densities, lens angles, temperatures and bitrates are sourced.
Verified against
- IEC 62676-4:2014 pixel densities (25 / 62.5 / 125 / 250 px/m), quoted in the foreword of IEC 62676-4:2025 (public preview, STN EN IEC 62676-4:2026); level definitions from Axis, Pixel density based on IEC 62676-4:2014.
- UK HSE, HSG140 Safe use and handling of flammable liquids, 2nd edition 2015, paras 214–220.
- EVS (Estonian standards body) catalogue page for EN 50050-2:2013, scope clause 1.3 (hand-held electrostatic powder equipment).
- Datasheets: CP Plus CP-UNC-TA41L3C-Q, CP-UNC-TA21L6C-Q, CP-UNC-TC41ZL6C-VMD-LQ; Axis ExCam XF Q1645.
- Kabe, POLYFLEX PES-50 powder technical data sheet, version 04, for a typical cure schedule.
- Hikvision, H.264(5) & H.264(5)+ Recommended Bit Rate at General Resolutions, read from a web.archive.org copy of the same file.
- IMD, heat-wave definitions.
- Checked 15 Oct 2026.
The fork: is the camera inside the classified area?
HSG140 (para 216) says electrical equipment "should be excluded from the booth, where possible". Anything that must be inside "should be designed and constructed for use in zone 1 or zone 2… according to the hazardous area classification", and "located to prevent it being covered with flammable residues". So the default is to watch the booth from outside, through its openings or a glazed panel, with an ordinary camera beyond the zone boundary. Use an Ex camera only where the zone drawing puts the camera inside a zone: booth interior, a mixing room with open thinner, or a powder booth.
Powder lines are a dust case, not a solvent case. Per EN 50050-2:2013 clause 1.3, electrostatic powder applicators are "category 2D for use in potentially explosive areas of zone 21 or 22, which have been generated by the equipment itself". A camera there needs a dust Ex marking such as Ex tb IIIC, EPL Db for zone 21 or Dc for zone 22. Whether PESO approval also applies, and how to read the marking, is on the explosion-proof CCTV and PESO page. This page does not restate it.
Task per view → pixel density
| View | Task | Level to plan for | px/m on target | Basis |
|---|---|---|---|---|
| Booth entry and exit, from outside | Parts going in and out, gaps on the conveyor, someone in the opening | Recognise | 125 | IEC 62676-4:2014 values |
| Conveyor hang (load) station | Empty hooks, hangers loaded, people at the station | Recognise | 125 | same |
| Conveyor unhang (unload) station | Parts taken off, rejects set aside, rack build-up | Recognise | 125 | same |
| Curing oven exit | Parts leaving, conveyor stopped or gapped | Observe to Recognise | 62.5–125 | same |
| Mixing room | Who is in the room, drums open, activity at the mixer | Observe | 62.5 | same |
Mapping hooks, racks and parts to these levels is our assumption; see the DORI explainer.
Lens from the formula
With R = horizontal pixels, d = slant distance to target (m), PPM = target px/m and HFOV = the lens's printed horizontal field of view:
- PPM = R ÷ (2 · d · tan(HFOV/2))
- Maximum HFOV for a target = 2 · atan(R ÷ (2 · d · PPM))
Example, booth entry: a 2688 px camera 4 m high and 8 m back is 8.94 m from the opening. For 125 px/m it needs 2·atan(2688 ÷ 2,235) = 100.5° or narrower. The CP Plus TA41L3C-Q 3.6 mm lens prints 78°, so it passes.
Vendor DORI runs longer: CP Plus prints Recognise at 17.1 m for the TA21L6C-Q 6 mm; the formula on its 54° gives 15.1 m. Plan on the formula figure. Run your own positions in the lens and DORI calculator.
Worked spec for a 1-booth + 1-oven line
Layout assumption: one overhead conveyor through load station, booth, curing oven and unload station, plus a separate mixing room.
| View (cameras) | Example camera (datasheet) | Pixels × HFOV | Mount height, distance (assumed) | Scene width (m) | px/m achieved | Level met | Zone status (assumed) |
|---|---|---|---|---|---|---|---|
| Booth entry (1) | CP Plus CP-UNC-TA41L3C-Q, 3.6 mm, 4 MP | 2688 × 78° | 4 m high, 8 m back (8.9 m slant) | 14.5 | 186 | Recognise | Outside zone |
| Booth exit (1) | CP Plus CP-UNC-TA41L3C-Q | 2688 × 78° | 4 m high, 8 m back | 14.5 | 186 | Recognise | Outside zone |
| Hang station (1) | CP Plus CP-UNC-TA41L3C-Q | 2688 × 78° | 5 m high, 7 m back (8.6 m slant) | 13.9 | 193 | Recognise | Outside zone |
| Unhang station (1) | CP Plus CP-UNC-TA41L3C-Q | 2688 × 78° | 5 m high, 7 m back | 13.9 | 193 | Recognise | Outside zone |
| Oven exit, off-axis (1) | CP Plus CP-UNC-TA21L6C-Q, 6 mm, 2 MP | 1920 × 54° | 5 m high, 10 m from oven mouth (11.2 m slant) | 11.4 | 169 | Recognise | Outside zone; heat limit applies |
| Mixing room (1) | Axis ExCam XF Q1645, 3.9–10 mm at wide end, 2 MP | 1920 × 85° | 3 m high, 6 m to far wall (6.7 m slant) | 12.3 | 156 | Recognise | Inside zone, Ex camera |
Cameras per N metres or per unit (rule of thumb, assumption):
- One per booth opening, per load or unload station, and per oven exit.
- One Ex camera per classified room.
- Long conveyor runs: a 2688 px, 78° camera reaches Recognise up to 13.3 m away, where it covers 2688 ÷ 125 = 21.5 m of conveyor seen side-on. Plan one per ~20 m.
Total for this line: 6 (5 ordinary, 1 Ex).
IP, IK, heat and light
| Item | Paint-shop spec | Source |
|---|---|---|
| Ingress | IP67 for anything near washers, pretreatment or hose-down | CP Plus sheets list "Weatherproof Standard IP67"; test meaning in the IP/IK guide |
| Impact | IK10 where hooks, racks or forklifts swing past | TC41ZL6C-VMD-LQ lists "IK10 (optional)"; the TA41L3C-Q and TA21L6C-Q sheets list no IK rating |
| Operating temperature | +60 °C max for CP Plus TA41L3C-Q, TA21L6C-Q and TC41ZL6C-VMD-LQ; −60 °C to 60 °C for Axis ExCam XF Q1645 | Datasheets |
| Oven side | Cure schedule 180 °C for 13 min to 210 °C for 4 min hold, object temperature, for one polyester-epoxy powder | Kabe TDS 11210, version 04 |
| Ex marking (example) | ATEX/IECEx: Ex db IIC T5 Gb and Ex tb IIIC T95°C Db; PESO: Ex db IIC T6 Gb, certificate A/P/HQ/KA/104/5735 | Axis ExCam XF Q1645 datasheet |
| Low light, IR | Colour 0.03 [email protected], IR 30 m (TA41L3C-Q); IR 60 m (TA21L6C-Q) | CP Plus datasheets |
The Q1645 datasheet lists no built-in IR illuminator, so the mixing room needs its own lighting at night.
Storage for 30 days
Per the Hikvision recommended-bitrate sheet at 25 fps, H.265 runs at 2,048 Kbps for 1080P and 4,096 Kbps for 2688×1520. That is 22.1 and 44.2 GB per camera per day. The CP Plus sheets cap H.265 at 6,144 Kbps.
| Cameras | Bitrate each (Kbps) | GB/day | 30 days (TB) | +30% margin (TB) |
|---|---|---|---|---|
| 4 × 4 MP (booth, stations) | 4,096 | 176.9 | 5.3 | 6.9 |
| 2 × 2 MP (oven exit, mixing room) | 2,048 | 44.2 | 1.3 | 1.7 |
| Total, 6 cameras | — | 221.2 | 6.6 | 8.6 |
The sheet advises 20–30% more "if the real environment is more complex". Size the disk with the NVR days table; the loading dock spec uses the same method.
What breaks in a paint shop
- Overspray on the lens. Keep cameras out of the airflow path from gun to extract; HSG140 asks the same of booth equipment.
- Solvent vapour. HSG140 (para 214) sets booth ventilation to keep vapour below 25% of the LEL. A ventilation failure can widen the zone, so mount ordinary cameras well clear of the boundary, not on it.
- Oven heat. The oven cures parts at 180–210 °C object temperature (Kabe TDS) while the camera tops out at +60 °C. One IMD heat-wave criterion is an actual maximum of 45 °C or more, so the margin left on a summer afternoon is small. Mount off-axis, never above the exit, and add a sunshield in a tin-roofed shed.
- Through-glass viewing. A camera looking into the booth through a glazed panel must have IR off and the lens against the glass, or IR reflects back.
- Nobody inside during cure. HSG140 (para 220) says no one should enter an oven or booth during drying or curing, so a camera inside is rarely worth it.
When to call the installer / what to ask the vendor
Get the hazardous-area drawing first. Ask for the printed HFOV at your focal length, the model's IK rating and temperature ceiling, and for any Ex camera the marking, Ta range and PESO letter. At handover, measure px/m on a hanger at each station.
Mama reads a factory's existing cameras over RTSP/ONVIF and tells the owner, in plain language, how long the line stood idle or ran with empty hooks. Hang and unhang cameras at Recognise level make that possible (askthemama.com). Leave an email or phone in the form below.
FAQ
Can I install a normal CCTV camera inside a paint booth? Only if the hazardous-area classification says that spot is unclassified, which is rare inside a solvent booth. HSG140 says electrical equipment should be kept out of the booth where possible; watch it from outside.
Do I need an explosion-proof camera for a powder coating booth? Inside the booth's dust zone, yes, a camera needs an Ex marking; the rules are in explosion-proof CCTV and PESO hazardous areas. Outside the zone, an ordinary IP67 camera is enough.