mama Get a free camera plan ☰

Loading Dock CCTV Specification: Bay Occupancy, Dwell Time, Lens, IP/IK and Storage for a 6-Bay Dock (India)

By The Mama Editorial Team · Factory-floor cameras, India compliance & operations

An owner's dock question is "which truck was at which bay, and for how long": bay occupancy and turnaround, not plates. A 6-bay dock answers it with about 8 cameras. Two apron cameras log arrival and departure at 25–62.5 px/m. Three inside cameras time each dock door from open to close at the 125 px/m Recognise level of IEC 62676-4:2014 (checked 14 Oct 2026).

Last checked: 14 Oct 2026. Layout figures are worked assumptions; densities, lens angles and bitrates are sourced.

Bay occupancy and dwell: two views, two clocks

A truck's time at the dock has two parts, and each needs its own view.

The gap between the two clocks is time a truck stood at a bay with its door shut. Mama reads a factory's existing cameras over RTSP/ONVIF and tells the owner, in plain language, how long bays and machines stood idle. Dock cameras placed to these two levels make that possible.

Bays per apron camera vs truck length vs occlusion

The apron camera is the weak link, because trucks hide each other. Assumed geometry: bays at 4 m centres, a camera 6 m high at the end of the dock face, the 2 MP CP Plus CP-UNC-TA21L6C-Q at its printed 54° HFOV, distance to the cab end of the farthest truck. Pixel density follows the IEC formula (DORI explainer).

Bays per apron camera Truck length into apron (assumed) Distance to farthest cab (m) px/m there Level met Bays a truck at the nearest bay can hide
2 7 m 11.0 171 Recognise 1
2 12 m 14.7 128 Recognise 1
3 7 m 13.6 139 Recognise 2
3 12 m 16.7 113 Observe 2
6 7 m 23.9 79 Observe 5
6 12 m 25.8 73 Observe 5

How to read it:

Pixel density for the other views

Staging lanes need Observe or better (62.5+ px/m) to count pallets; the gate needs 300–440 px/m for plates and Identify (250 px/m) for drivers. Mapping pallets to these levels is our assumption. The IEC 2025 edition redefines the levels, but Indian datasheets still print the 2014 scale. Size lenses from the printed horizontal field of view (HFOV), not focal length: the "1/2.8-inch" label is not a physical width, and wide lenses are not rectilinear. The formula and its limits are in the DORI explainer; run your own positions in the lens and DORI calculator.

Worked spec for a 6-bay dock

The layout is an assumption: 6 bays at 4 m centres (24 m dock face), a 10 m deep staging area inside, a 30 m yard apron and one gate lane.

View (cameras) Example camera from datasheet Pixels × HFOV Mount height, distance (assumed) Scene width (m) px/m achieved Level met IR range (datasheet)
Inside, 2 bays each (3) CP Plus CP-UNC-TA41L3C-Q, 3.6 mm, 4 MP 2688 × 78° 6 m high, 10 m back (11.7 m slant) 18.9 142 Recognise 30 m
Staging lanes, one from each end wall (2) CP Plus CP-UNC-TA41L3C-Q 2688 × 78° 5 m high, 12 m to mid-dock (13 m slant) 21.1 128 Recognise (edge) 30 m
Yard apron, one from each end of the dock (2) CP Plus CP-UNC-TA21L6C-Q, 6 mm, 2 MP 1920 × 54° 6 m high, far bay 30 m away (slant) 30.6 63 Observe (at the limit) 60 m
Gate lane, plates and drivers (1) Prama PT-NC326P1-WNRAM(D2), 2.7–13.5 mm at tele, 2 MP 1920 × 33.4° 4 m high, 8 m capture distance (8.9 m slant) 5.4 358 (122 px on a 340 mm plate) Plate; Identify 50 m

The apron row is the worst case: far bay plus yard depth, 30 m. CP Plus prints Recognise at 15.2 m for the TA41L3C-Q; the formula gives 13.3 m at 125 px/m, so plan on the formula figure.

Cameras per N bays (rule of thumb, assumption):

The gate camera, briefly

Plates belong to the gate, not the dock. Axis says "most LPR software require around 100–150 pixels over the full width of the plate", derived from a European plate. Applied to the 340 mm Indian HSRP width, that is 294–441 px/m (our assumption; 200–300 px/m on a 500 mm plate). Axis keeps the total angle to the vehicle under 30° (here atan(4/8) = 26.6°) and advises that on-camera LPR should typically not exceed 2 MP. The Prama varifocal meets this at its 33.4° tele end.

IP, IK, light and heat

Item Spec for a dock Source
Ingress IP66 or IP67 outside, IP67 at the door line CP Plus datasheets list "Weatherproof Standard IP67"; test meaning in the IP/IK guide
Impact IK10 for anything inside forklift or tail-lift reach Neither CP Plus sheet above lists an IK rating. The Prama PT-NC326P1-WNRAM(D2) and Honeywell HC50WB5R2 list IK10.
Low light Colour 0.03 [email protected], 0 lux with IR on (TA41L3C-Q); 0.001 [email protected] colour (TA21L6C-Q) CP Plus datasheets
IR Datasheet IR range above the farthest target in the view: 30 m inside, 60 m on the apron CP Plus datasheets (IR range); the rule is ours
Backlight True WDR in dB for cameras facing an open door CP Plus sheets list only "DWDR". Honeywell HC50WB5R2 lists WDR at 130 dB.

Storage for 30 days

Per the Hikvision recommended-bitrate sheet at 25 fps, H.265 runs at 2,048 Kbps for 1080P and 4,096 Kbps for 4 MP (2560×1440 and 2688×1520). That is 22.1 and 44.2 GB per camera per day. Both CP Plus sheets cap H.265 at 6,144 Kbps.

Cameras Bitrate each (Kbps) GB/day 30 days (TB) +30% busy-scene margin (TB)
5 × 4 MP (inside, staging) 4,096 221.2 6.6 8.6
3 × 2 MP (apron, gate) 2,048 66.4 2.0 2.6
Total, 8 cameras — 287.5 8.6 11.2

The sheet advises 20–30% more "if the real environment is more complex". It has its own 2688×1520 row, at the same 4,096 Kbps, so the figure fits the CP Plus 4 MP stream. Size the disk with the storage table.

What breaks at a loading dock

When to call the installer / what to ask the vendor

Ask for the HFOV at your focal length, true WDR in dB and the IK rating of the exact model. At handover, park trucks at both end bays and check what each apron camera still sees of the middle doors. Then measure px/m at the far bay and at the door line, by day and at night. Background: camera resolution and lens for a factory floor.

To get a camera plan for your own dock layout from Mama (askthemama.com), leave an email or phone in the form below.

FAQ

How can CCTV measure truck turnaround time at a loading dock? The apron camera logs arrival and departure at a bay; the inside camera logs door open and close. Dwell minus door-open time is the time a truck waited at a closed door.

How many bays can one loading dock camera cover? In the worked geometry, a 2 MP camera at 54° still reaches Observe at the farthest of 6 bays. The limit is occlusion: a truck at the nearest bay hides the door line of every bay behind it, so 2–3 bays per apron camera is safer when the end bays are busy.

How many cameras do I need for a 6-bay loading dock? About 8 for the layout above: 3 inside, 2 for staging, 2 on the apron and 1 at the gate.

Where should the inside dock camera be mounted? The worked example assumes 5–6 m, above forklift masts, about 10 m back, one camera per pair of doors.

Verified against

Last verified 14 Oct 2026 against the vendor and regulator documents listed above. Found an error? Tell Mama in the form below.

Read next
Free · no obligation

Get a camera plan for your floor

Tell Mama about your plant and Mama will come back with how many cameras you need, where they go, and the retention your state expects — sized to your floor, in ₹. Built for Indian factories.

  • How many cameras & exact placement
  • Compliance-ready (BIS/STQC, women's night shift)
  • Honest ₹ estimate — guard vs camera-AI