IP66 vs IP67 vs IP68 and IK10 for Factory CCTV Cameras: What the Tests Actually Mean

By The Mama Editorial Team · Factory-floor cameras, India compliance & operations

Under IEC 60529 (India: IS/IEC 60529), IP66 means dust-tight plus 100 L/min water jets from 2.5–3 m; IP67 means dust-tight plus 30 minutes under 1 m of water. IP68 depth and time are agreed with the manufacturer. IK08 is 5 J, IK10 is 20 J (IEC 62262:2002; India: IS 17050). For factory floors, ask for IP66/IP67 plus IK10.

Verified against

IP and IK test conditions at a glance

Code What the standard says Test, as written Source
IP5X Dust-protected: "ingress of dust is not totally prevented" but must not interfere with operation Talc dust chamber; the enclosure is treated as category 1 (under-pressure) unless the product standard says otherwise IS/IEC 60529 Table 2, 13.5
IP6X Dust-tight: "no ingress of dust" Talc that passes a 75 µm mesh, 2 kg per m³ of chamber. Enclosure always held below ambient pressure (max 2 kPa) to draw 80 volumes of air, up to 8 h. Pass = no visible dust inside IS/IEC 60529, 13.4, 13.6
IPX5 Water jets 6.3 mm nozzle, 12.5 L/min ±5%, 2.5–3 m, 1 min per m², minimum 3 min IS/IEC 60529, Table 8, 14.2.5
IPX6 Powerful water jets 12.5 mm nozzle, 100 L/min ±5%, 2.5–3 m, 1 min per m², minimum 3 min IS/IEC 60529, Table 8, 14.2.6
IPX7 Temporary immersion Lowest point 1 m below the surface (enclosures under 850 mm tall), 30 min, water within 5 K of the equipment IS/IEC 60529, 14.2.7
IPX8 Continuous immersion Unless a product standard applies, conditions are "subject to agreement between manufacturer and user", but more severe than IPX7 IS/IEC 60529, Table 3, 14.2.8
IPX9 High-pressure, high-temperature water jet Added by Amendment 2 (2013). Not in the 2001 text that BIS adopted IEC 60529 Ed 2.2 preview
IK08 5 J impact 1.7 kg steel hammer, 0.300 m drop Rittal white paper (IEC 62262:2002 values), Tables 1 and 4
IK10 20 J impact 5 kg steel hammer, 0.408 m drop Rittal, Tables 1 and 4
IK11 Added by Amendment 1 (2021) IK numerals now run 00 to 11; joule value not shown in the preview IEC 62262 Ed 1.1 preview, 4.1

Three rules in the standard change how you read a datasheet:

  1. Up to IPX6, higher includes lower. An IPX6 enclosure is also taken to meet IPX5 and below.
  2. IPX7 and IPX8 do not include IPX5 or IPX6. The standard's table lists a bare "IPX7" or "IPX8" as restricted, meaning immersion only and unsuitable for water jets. A camera that passed both is marked IPX6/IPX7 ("versatile"), so on a camera you would see "IP66/IP67" (IS/IEC 60529, clause 6).
  3. IP68 has no fixed depth or time. Read the datasheet for the declared metres and hours. If either is missing, the claim cannot be checked.

Which rating for which factory zone

Zone Rating to ask for Why, per the standards
Cement, flour, grinding, textile lint IP6X (IP66 or IP67) IP5X lets some dust in by definition. IP6X is tested under suction, which matches a camera that heats and cools and so breathes
Monsoon exposure, open sheds, yard poles IP66, or IP66/IP67 where water can pool The IPX6 jet is far harsher than rain, but the test lasts minutes, not a season
Hose-down cleaning (dairy, food, pharma) IPX9 from a test report, or a cleaning regime agreed with the vendor; not IP66 alone Clause 6: tests use fresh water, and "actual protection may not be satisfactory if cleaning operations with high pressure and/or solvents are used"
Flood-prone basements, drains, effluent pits IP68 with stated depth and hours IPX8 conditions are agreed between manufacturer and user, not fixed by the standard
Forklift aisles, loading bays, reachable heights IK10 20 J is a 5 kg hammer dropped 0.408 m, not a vehicle (see below)

Where brands differ

A bare "IP67" is common on datasheets. By the letter of the standard, the jet claim is yours to ask for.

What breaks in a factory

The scope clause of IS/IEC 60529 says these are outside the IP code and belong to the product standard: mechanical impact, corrosion, corrosive solvents ("for example, cutting liquids"), fungus, vermin, solar radiation, icing, condensation and explosive atmospheres. In practice:

When to call the installer / what to ask the vendor

Mama reads existing cameras over RTSP/ONVIF and tells the owner, every morning, which machines stood idle and for how long. Leave an email or phone in the form below.

FAQ

Is IP67 better than IP66? Not strictly. IP67 adds a 30-minute, 1 m immersion test, but by IEC 60529 a camera marked only "IP67" makes no claim about water jets. For outdoor and wash-prone positions, ask for IP66/IP67. For a full zone-by-zone pick, see turret vs bullet placement.

Is IP68 better than IP67? Only for continuous immersion. The standard requires IPX8 to be more severe than IPX7, but the depth and time are agreed between manufacturer and user (in practice, declared on the datasheet), and IPX8 does not imply jet resistance either.

What does IK10 mean on a CCTV camera? The enclosure withstood 20 J impacts, which Rittal describes as a 5 kg hammer dropped from 0.408 m, without losing its function or its declared protection. IEC 62262 added IK11 in 2021.

Is IP66 enough for heavy monsoon rain? For rain, yes: IPX6 is tested with 100 L/min jets. It does not cover internal condensation, corrosion or high-pressure washdown.

Last verified 13 Oct 2026 against the vendor and regulator documents listed above. Found an error? Tell Mama in the form below.

Read next
Free · no obligation

Get a camera plan for your floor

Tell Mama about your plant and Mama will come back with how many cameras you need, where they go, and the retention your state expects — sized to your floor, in ₹. Built for Indian factories.

  • How many cameras & exact placement
  • Compliance-ready (BIS/STQC, women's night shift)
  • Honest ₹ estimate — guard vs camera-AI

Mama replies by email or phone — whichever you left. No spam, no obligation.