mama Get a free camera plan ☰

Factory Perimeter and Boundary Wall CCTV Specification: Cameras per 100 m, Night Reach, Lens and Storage (India)

By The Mama Editorial Team · Factory-floor cameras, India compliance & operations

How many cameras does a 400 m factory boundary wall need to see a person at night? About 3 per 100 m with a 4 MP, 6 mm, 60 m-IR bullet at Observe density (62.5 px/m, IEC 62676-4:2014), checked 15 Oct 2026. The worked plant below needs 16, and 25 if line-crossing alarms must work.

Last checked: 15 Oct 2026. The plant layout is a worked assumption; everything else is sourced.

Verified against

Task per view → pixel density

View Question the owner asks Level to plan for px/m on target Basis
Along the wall, at night Is anyone on or at the wall? Detect (minimum) 25 IEC 62676-4:2014 values
Along the wall, at night Person or dog? How many? Observe (plan for this) 62.5 IEC 62676-4:2014 values
Each corner Did anyone come over where two walls meet? Observe 62.5 IEC 62676-4:2014 values
Rear gate Who walked or drove through? Same person as before? Recognise 125 IEC 62676-4:2014 values

Axis defines Observation as able to "determine how many people are present"; telling a person from a stray dog needs that level, so the wall is planned at Observe. Method: DORI explainer, as in the loading dock spec. The main gate is covered in the gate and weighbridge guide.

Lens and night reach from the formula

With R = horizontal pixels, d = distance (m), PPM = target px/m and HFOV = the printed horizontal angle of view:

Wall cameras sit inside the wall, 5 m high, all looking the same way along it, so each covers the blind zone under the next. The blind zone ends where the frame bottom meets the ground with the frame centre aimed at the far end of the reach (assumption). Run your own wall in the lens and DORI calculator.

Cameras per 100 m of wall

Camera (datasheet) R × HFOV / VFOV IR range (m) Detect d_max (m) Observe d_max (m) Night reach at Observe (m) Blind zone (m) Cameras per 100 m
CP Plus CP-UNC-TA21L6C-Q, 2 MP, 6 mm 1920 × 54° / 29° 60 75.4 30.1 30.1 11.3 5.3
CP Plus CP-UNC-TA41L6C-Q, 4 MP, 6 mm 2688 × 49° / 26° 60 118.0 47.2 47.2 14.5 3.1
CP Plus CP-UNC-TC41ZL6C-VMD-LQ at 13.5 mm 2688 × 28° / 16° 60 IR + 60 warm light 215.6 86.2 60 (IR-limited) 22.1 2.6
Honeywell HC50WB5R2 at 13.5 mm 2592 × 28.5° / 21.4° 70 204.1 81.6 70 (IR-limited) 18.9 2.0

Past the 60–70 m IR range, extra zoom buys nothing at night. A 2 MP 6 mm camera needs about 70% more units than a 4 MP one. Vendor DORI lines run longer: CP Plus prints Observe at 49.6 m for the TA41L6C-Q; the formula from its own 49° HFOV gives 47.2 m.

Line-crossing analytics need a shorter reach

Hikvision's perimeter guide (24 Dec 2018) recommends monitoring "within 50 meters": 30 m for a 6 mm lens, 40 m for 8 mm, 50 m for 12 mm. It asks for the optical axis more than 15° below horizontal and an outdoor height of 3–8 m, "higher than the fence".

It sets target height between 1/16 and 1/2 of frame height: a 1.7 m person at 30 m on the TA41L6C-Q is about 186 px, above the 95 px minimum.

At 15° tilt the TA41L6C-Q's blind zone is 9.4 m, so spacing is 20.6 m: 4.9 cameras per 100 m. These are Hikvision's limits for its own NVR analytics. Check the datasheet: the TC41ZL6C-VMD-LQ lists "Tripwire, Intrusion"; the TA41L6C-Q lists motion, IMD and human body detection, but no tripwire.

Worked plan: a 400 m wall (assumption-labelled)

Assumed plant: main-gate face handled by gate cameras; two 125 m side walls; a 150 m rear wall along a nala with a 6 m rear gate; two rear corners.

View Camera Position Computed at target Count (recording) Count (line-crossing)
Side walls, 2 × 125 m CP-UNC-TA41L6C-Q 5 m, inside the wall 62.5 px/m at 47 m 4 + 4 7 + 7
Rear wall, 150 m (nala side) CP-UNC-TA41L6C-Q 5 m, inside the wall 62.5 px/m at 47 m 5 8
Rear corners CP-UNC-TA41L3C-Q, 3.6 mm, 78° 20 m back on the diagonal 82 px/m, 32.7 m wide scene 2 2
Rear gate CP-UNC-TA41L3C-Q 4 m high, 8 m inside the gate 198 px/m, 13.6 m wide scene 1 1
Total 16 25

The corner camera's 30 m IR covers its 20 m slant. The rear gate camera reaches Recognise, not Identify (250 px/m); for faces, add a closer camera.

IP, IK, light and power

Item Spec for a boundary wall Source
Ingress IP67 on all four example cameras; Honeywell lists IP66 and IP67 Datasheets; test meanings in the IP/IK guide
Impact IK10 where a stone or a stick can reach the camera TA41L6C-Q lists none; TC41ZL6C-VMD-LQ "IK10 (optional)"; HC50WB5R2 IK10
Low light 0.001 [email protected] colour, 0 lux with IR on (TA41L6C-Q, TA21L6C-Q); 0.03 [email protected] colour (TA41L3C-Q) CP Plus datasheets
Heat –40 to +60 °C (TA41L6C-Q); –30 to +60 °C (TC41ZL6C); Honeywell –30 to 60 °C "(IR off)" Datasheets
PoE draw, maximum 6.8 W (TA41L6C-Q); 12.7 W with warm light (TC41ZL6C); 12.95 W (HC50WB5R2) Datasheets

Hikvision's guide recommends "lighting supplement or low light cameras" for dark scenes. Floodlights let a colour camera use its full px/m distance instead of the IR range. On a dark nala side, thermal is the other option; it shows a heat outline, not a face.

Cable runs over 100 m

The CP-DNW-HP4H1-48 switch sheet gives "0-100m/100Mbps; Max. 250m/10Mbps via Cat.5e or more under Extend mode". On a 125 m side wall the far camera is beyond 100 m from a front rack. A 4 MP H.265 stream at 15 fps (2,048 Kbps, Hikvision table) fits one 10 Mbps port.

That switch has a 48 W PoE budget: four TC41ZL6C cameras at 12.7 W (50.8 W) exceed it. The CP-ANW-HP4H1-6 has 60 W, 6 kV surge protection and a 0–40 °C range, so mount it in a shaded, ventilated box. Beyond 250 m, run fibre to a field switch. Size power with the PoE budget calculator.

Storage for 30 days

Per the Hikvision bitrate sheet, H.265 at 2688×1520 runs 4,096 Kbps at 25 fps and 2,048 Kbps at 15 fps: 44.2 and 22.1 GB per camera per day.

Cameras Frame rate Bitrate each (Kbps) GB/day 30 days (TB) +30% margin (TB)
16 × 4 MP 15 fps 2,048 353.9 10.6 13.8
16 × 4 MP 25 fps 4,096 707.8 21.2 27.6
25 × 4 MP 15 fps 2,048 553.0 16.6 21.6

The sheet advises 20–30% more "if the real environment is more complex"; rain, trees and grainy night IR qualify. Check disk days in the NVR days table.

What breaks on a perimeter

When to call the installer / what to ask the vendor

Ask for the HFOV at your focal length, the IR range, the exact model's IK rating, whether tripwire runs on the camera or the NVR, and the switch's extend-mode limits. At handover, walk the wall at night and check a person is visible at the far end of every stretch. Theft context: theft and shrinkage in Indian factories.

Mama reads a factory's existing cameras over RTSP/ONVIF and tells the owner, in plain language, where machine hours were lost (askthemama.com). Leave an email or phone in the form below.

FAQ

How many CCTV cameras do I need for a boundary wall? About 3 per 100 m for a 4 MP, 6 mm, 60 m-IR bullet at Observe density; about 5 if line-crossing alarms must work. Add corners and gates.

How far can a CCTV camera see at night? No farther than its IR range, whatever the zoom. The 4 MP CP-UNC-TA41L6C-Q reaches Observe density at 47 m and lists 60 m IR.

What is the maximum cable length for an IP camera? 100 m at 100 Mbps per the CP Plus CP-DNW-HP4H1-48 sheet; 250 m at 10 Mbps in extend mode. Beyond that, fibre.

Last verified 15 Oct 2026 against the vendor and regulator documents listed above. Found an error? Tell Mama in the form below.

Read next
Free · no obligation

Get a camera plan for your floor

Tell Mama about your plant and Mama will come back with how many cameras you need, where they go, and the retention your state expects — sized to your floor, in ₹. Built for Indian factories.

  • How many cameras & exact placement
  • Compliance-ready (BIS/STQC, women's night shift)
  • Honest ₹ estimate — guard vs camera-AI

Mama replies by email or phone — whichever you left. No spam, no obligation.