CP Plus documents two RTSP paths on port 554: rtsp://user:pass@ip:554/cam/realmonitor?channel=1&subtype=0 (Q-series and TS41PL3 manuals) and rtsp://user:pass@ip:554/video/live?channel=1&subtype=0 (LQ-series manual). subtype=0 is main stream, 1 is sub stream. Default camera IP is 192.168.1.250; the ONVIF user is a separate account, default admin.

Verified against

CP Plus RTSP URL variants and defaults

Item Value Applies to Source
RTSP URL (main stream) rtsp://username:password@ip:port/cam/realmonitor?channel=1&subtype=0 Q-series and TS41PL3 cameras Q manual v2.01, §4.4.2 Port; TS41PL3 manual v1.0.1
RTSP URL (sub stream, ch 2) rtsp://admin:[email protected]:554/cam/realmonitor?channel=2&subtype=1 Example in TS41PL3 manual TS41PL3 manual v1.0.1
RTSP URL (LQ series) rtsp://username:password@ip:port/video/live?channel=1&subtype=0 LQ-series cameras LQ web manual v1.0.3, §5.2.2 Port
channel Starts from 1 Cameras Q manual v2.01
subtype 0 = main stream, 1 = sub stream Cameras Q manual v2.01; TS41PL3 manual
Without login rtsp://ip:port/cam/realmonitor?channel=1&subtype=0 When auth not required TS41PL3 manual
RTSP port 554 Cameras, NVR, DVR All five CP Plus manuals above (NVR/DVR: Manage > Network > Connection)
RTSP login mode Digest by default (selected models) Q-series Q manual v2.01, Basic Services
HTTP / HTTPS / TCP / UDP 80 / 443 / 25001 / 25002 LQ camera; NVR LQ manual; NVR manual
Default IP Camera 192.168.1.250; NVR 192.168.1.245; DVR 192.168.1.240 — Q, LQ, NVR and DVR manuals
Default user admin, password set at initialisation Camera LQ manual §2.1
ONVIF service Enabled by default (camera: ONVIF server; NVR: adding ONVIF cameras) Camera, NVR Q manual Table 4-23; LQ manual Table 5-41; NVR manual §4.5.2.1
ONVIF user Separate account; default ONVIF user admin Camera, NVR Q manual §4.7.2.4; NVR manual §4.6.2
Concurrent stream users 6 ("Total bandwidth: 36 M") CP-UNC-TA41L3C-D-LQ Datasheet

Two documentation faults. First, the Q manual's examples are broken: it prints channel=21&= 1 and channel=11&=0 where it means channel=2&subtype=1 and channel=1&subtype=0 — copy the format line, not the example. Second, CP Plus does not say whether the /video/live and /cam/realmonitor paths are interchangeable; treat the path as model-specific and read it from the manual of the exact model.

Users report other paths on older or budget CP Plus models (/live/channel1, /live/av0, /VideoInput/1/mpeg4/1) on the crowdsourced ispyconnect list; CP Plus does not document these in any manual we found.

Menu paths (per manual version)

Q-series camera (manual v2.01): RTSP port at (settings icon) > Network Settings > Port; ONVIF on/off and RTSP Login Mode at (settings icon) > Network Settings > Basic Services; ONVIF accounts at (settings icon) > System > Account > ONVIF User; codec at (settings icon) > Camera > Encode > Encode.

LQ-series camera (web manual v1.0.3): codec and sub-streams at Setting > Camera > Video > Video; ONVIF service at Setting > System > Safety > System Service. The manual does not print a click-path for the rest, only sections: RTSP port in §5.2.2 Port (under Network), ONVIF accounts in §5.5.2.b ONVIF User (under Account), digest algorithm for ONVIF in §5.5.3.e Digest Algorithm for Authentication (under Safety).

NVR (29 Jul 2026 manual): ONVIF service at Manage > Security > System Service > Basic Services; ONVIF accounts at Manage > Account > ONVIF User; digest choice at Manage > Security > Security Authentication > Digest Algorithm for Authentication.

Discovery: CP Plus ships IP Finder (V4.0 on its software page: batch modify IP, batch initialise, reset locked passwords). The Q manual also says the camera can be initialised through "ConfigTool" or "DSS Pro"; CP Plus's software page does not list either tool.

Settings that matter for third-party analytics

Where brands differ: CP Plus vs Dahua

Item CP Plus (manuals above) Dahua (Web 3.0 manual / Dahua Wiki)
RTSP path /cam/realmonitor?channel=&subtype= (Q, TS41PL3); /video/live?... (LQ) /cam/realmonitor?channel=&subtype=
Default camera IP 192.168.1.250 192.168.1.108
Default TCP port 25001 37777
Reserved ports note "0~1024, 37780~37880, 1900, 3800, 5000, 5050, 9999, 37776, 39999, 42323" (LQ manual) Identical list
Subtype values 0 main, 1 sub 0 main, 1 extra 1, 2 extra 2

The LQ manual's reserved-port list and its BlackBerry/H.264B note are word-for-word the Dahua Web 3.0 text, and the /cam/realmonitor URL is identical. This is a document-level similarity only: CP Plus documentation does not state any relationship with Dahua, and this page does not infer one. The top brands guide covers the ownership side. CP Plus does not document subtype=2 for a third stream, even on triple-stream models; it is not confirmed.

What breaks in a factory

When to call the installer / what to ask the vendor

Ask for: model and firmware of every camera and the NVR; the RTSP path that firmware uses; the ONVIF account and password; sub-stream settings; the IP plan. For new purchases, check the model on the STQC-certified list. Our Indian brands RTSP/ONVIF cheat sheet has the same fields for other brands.

Where Mama fits

Mama reads a plant's existing cameras over RTSP/ONVIF — typically the sub stream — and reports to the owner how long each machine sat idle, so a correctly set CP Plus feed is all it needs. The retrofit guide explains what an existing system must have. Leave an email or phone in the form below.

FAQ

I cannot add my CP Plus DVR to Home Assistant through ONVIF or RTSP. What URL works? This was asked on the Home Assistant forum in 2022. A user there reports rtsp://<ip>/cam/realmonitor?channel=3&subtype=0 with the channel changed per camera — the same format CP Plus documents for cameras. For ONVIF, use the device's ONVIF User account, which CP Plus manuals keep separate from the web login.

What is the correct RTSP URL for CP Plus cameras? A ZoneMinder forum thread is titled "Looking for the correct URL for cameras from CP Plus". Per CP Plus manuals: /cam/realmonitor?channel=1&subtype=0 for Q-series and TS41PL3, /video/live?channel=1&subtype=0 for LQ-series, port 554. Check the manual for your exact model.

Last verified 7 Oct 2026 against the vendor and regulator documents listed above. Found an error? Tell Mama in the form below.

Free · no obligation

Get a camera plan for your floor

Tell Mama about your plant and Mama will come back with how many cameras you need, where they go, and the retention your state expects — sized to your floor, in ₹. Built for Indian factories.

  • How many cameras & exact placement
  • Compliance-ready (BIS/STQC, women's night shift)
  • Honest ₹ estimate — guard vs camera-AI

Mama replies by email or phone — whichever you left. No spam, no obligation.