STQC-Certified CCTV Cameras for Factories (India, Checked Sep 2026)
By the Mama Editorial Team. Last verified: 29 September 2026, against the STQC IoTSCS certified product list (Essential Requirements) and each manufacturer's published datasheet.
The table below lists 40 PoE IP cameras from four brands (Prama, CP Plus, Matrix and Honeywell). We found each model by name in a STQC Essential Requirements (ER) certificate on stqc.gov.in and checked its specs on the maker's own datasheet on 29 September 2026. Those 40 models sit on 18 certificates, and every certificate is valid until at least March 2028. To check a model yourself, open the certificate PDF linked in its row and find the exact model string, suffix included. Then search the same model on the BIS CRS portal (crsbis.in) for its R-number.
One thing to know before you use any "STQC list": STQC's page for network cameras now carries a notice that the list "is no longer being updated and is retained solely for historical reference". The same page cites a MeitY circular dated 04.02.2026. Since then, STQC issues its security test report under the Compulsory Registration Order, which is the BIS registration route, instead of as a separate certificate. So certificates already on the STQC list still carry their printed expiry dates, but any camera certified after January 2026 will show up on BIS CRS, not on the STQC page. That is why this list can only grow if we check both registers every month.
How to use this list
Filter the "Suggested zone" column by the part of your floor you are planning. We base each tag on the datasheet, using a written rule, not a judgement of image quality:
- line: dome, turret or motorised-varifocal models. Mounted over a machine or conveyor, these let you frame the work area tightly. Use 4 MP and above where you need to read gauges or count parts.
- dust: IP67-rated models with a dome or turret body. Dust cannot get in, and the smooth front is easy to wipe in lint, flour, cement or grinding dust. Models that also list IK10 are impact-rated, which matters in forklift aisles.
- night: IR reach of 50 m or more, or a dual-light / warm-light model that can switch to colour at night. Use this for the third shift, unlit yards and stores.
- gate: bullets with 50 m or more of IR, and preferably a motorised varifocal lens, for the main gate, the weighbridge and the loading bay. For number plates you still need a dedicated ANPR camera. None in this table is sold as ANPR.
- heat: not tagged per row. Every model here is rated to a maximum of +60 °C operating temperature on its datasheet. In a furnace bay, forging shop or tin-roof shed, measure the air temperature at the mounting point in May before you buy. If it goes above 60 °C, no camera in this table is rated for that spot without a cooled housing.
Two practical notes from the certificates themselves:
- The suffix matters. A certificate covers the exact string it prints. Matrix, for example, certified the "P2" variants (such as "SATATYA CIBR50FL40CWP P2"), and Prama certified the "(D2)" variants. A quote that drops the suffix is a different product until proved otherwise.
- Firmware matters too. Each certificate says it "applies only to specific version and release of the product in its evaluated configuration", and the annexure lists the firmware version tested. When the cameras arrive, ask the installer to show that the firmware is the certified release or a later one approved by the maker.
The list: 40 certified factory cameras
"Valid until" is the expiry date printed on the STQC certificate. Click the model name for the manufacturer's datasheet, and the certificate number for the PDF on stqc.gov.in.
| # | Brand | Model | Type | MP | ER/STQC certificate | Valid until | IP rating | IR range | RTSP / ONVIF (datasheet) | Suggested zone | Checked on |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | Prama | PT-NC340P3-WNM(D2) | Bullet | 4 | STQC/IoTSCS/ER/073 | 23.11.2028 | IP67, IK10 | 40 m (IR + white light) | RTSP; ONVIF S/G/T | night, line | 29.09.2026 |
| 2 | Prama | PT-NC320P3-WNM(D2) | Bullet | 2 | STQC/IoTSCS/ER/073 | 23.11.2028 | IP67, IK10 | 40 m (IR + white light) | RTSP; ONVIF S/G/T | night | 29.09.2026 |
| 3 | Prama | PT-NC341P3-WNAM(D2) | Dome | 4 | STQC/IoTSCS/ER/074 | 23.11.2028 | IP67, IK10 | 40 m (IR + white light) | RTSP; ONVIF S/G/T | dust, line, night | 29.09.2026 |
| 4 | Prama | PT-NC321P3-WNAM(D2) | Dome | 2 | STQC/IoTSCS/ER/074 | 23.11.2028 | IP67, IK10 | 40 m (IR + white light) | RTSP; ONVIF S/G/T | dust, line | 29.09.2026 |
| 5 | Prama | PT-NC34TP3-4NAM(D2) | Bullet | 4 | STQC/IoTSCS/ER/075 | 23.11.2028 | IP67, IK10 | 90 m | RTSP; ONVIF S/G/T/M | gate, night | 29.09.2026 |
| 6 | Prama | PT-NC32TP3-4NAM(D2) | Bullet | 2 | STQC/IoTSCS/ER/075 | 23.11.2028 | IP67, IK10 | 90 m | RTSP; ONVIF S/G/T/M | gate, night | 29.09.2026 |
| 7 | Prama | PT-NC347P3-WNRAM(D2) | Dome, motorised varifocal | 4 | STQC/IoTSCS/ER/076 | 23.11.2028 | IP67, IK10 | 40 m (IR + white light) | RTSP; ONVIF S/G/T | line, dust | 29.09.2026 |
| 8 | Prama | PT-NC346P3-WNRAM(D2) | Bullet, motorised varifocal | 4 | STQC/IoTSCS/ER/077 | 23.11.2028 | IP67, IK10 | 60 m (IR + white light) | RTSP; ONVIF S/G/T | gate, night, line | 29.09.2026 |
| 9 | Prama | PT-NC326P3-WNRAM(D2) | Bullet, motorised varifocal | 2 | STQC/IoTSCS/ER/077 | 23.11.2028 | IP67, IK10 | 60 m (IR + white light) | RTSP; ONVIF S/G/T/M | gate, night | 29.09.2026 |
| 10 | Prama | PT-NC361P1-WNMS(D2) | Dome | 6 | STQC/IOTSCS/ER/059 | 09.09.2028 | IP67 | 30 m (IR + white light) | RTSP; ONVIF S/G/T | line, dust | 29.09.2026 |
| 11 | Prama | PT-NC341P1-WNAMS(D2) | Dome | 4 | STQC/IOTSCS/ER/059 | 09.09.2028 | IP67 | 30 m (IR + white light) | RTSP; ONVIF S/G/T | line, dust | 29.09.2026 |
| 12 | Prama | PT-NC323P1-WNM(D2) | Turret | 2 | STQC/IOTSCS/ER/060 | 09.09.2028 | IP67 | 30 m (IR + white light) | RTSP; ONVIF S/G/T | line, dust | 29.09.2026 |
| 13 | Prama | PT-NC323P1-N(D2) | Turret | 2 | STQC/IOTSCS/ER/060 | 09.09.2028 | IP67 | 30 m (IR) | RTSP; ONVIF S/T | line, dust | 29.09.2026 |
| 14 | Prama | PT-NC347P1-WNRAM(D2) | Dome, motorised varifocal | 4 | STQC/IOTSCS/ER/061 | 09.09.2028 | IP67, IK10 | 40 m (IR + white light) | RTSP; ONVIF S/G/T | line, dust | 29.09.2026 |
| 15 | Prama | PT-NC327P1-WNRAM(D2) | Dome, motorised varifocal | 2 | STQC/IOTSCS/ER/058 | 09.09.2028 | IP67, IK10 | 40 m (IR + white light) | RTSP; ONVIF S/G/T | line, dust | 29.09.2026 |
| 16 | Prama | PT-NC360P1-WNMS(D2) | Bullet | 6 | STQC/IOTSCS/ER/062 | 09.09.2028 | IP67 | 30 m (IR + white light) | RTSP; ONVIF S/G/T | night | 29.09.2026 |
| 17 | Prama | PT-NC320P1-WNM(D2) | Bullet | 2 | STQC/IoTSCS/ER/100 | 30.10.2028 | IP67 | 30 m (IR + white light) | RTSP; ONVIF S/G/T | night | 29.09.2026 |
| 18 | Prama | PT-NC320P1-N(D2) | Bullet | 2 | STQC/IoTSCS/ER/100 | 30.10.2028 | IP67 | 30 m (IR) | RTSP; ONVIF S/T | night | 29.09.2026 |
| 19 | CP Plus | CP-UNC-TA41L3C-D-LQ | Bullet | 4 | STQC/IOTSCS/ER/021 | 22.06.2028 | IP67 | 30 m IR + 30 m warm light | RTSPS; ONVIF S/G/T | night | 29.09.2026 |
| 20 | CP Plus | CP-UNC-TA21L3C-LQ | Bullet | 2 | STQC/IOTSCS/ER/021 | 22.06.2028 | IP67 | 30 m IR + 30 m warm light | RTSPS; ONVIF S/G/T | night | 29.09.2026 |
| 21 | CP Plus | CP-UNC-DA41L3C-D-LQ | Dome | 4 | STQC/IOTSCS/ER/021 | 22.06.2028 | IP67 | 30 m IR + 30 m warm light | RTSPS; ONVIF S/G/T | line, night | 29.09.2026 |
| 22 | CP Plus | CP-UNC-TC41L5C-VMD-LQ | Bullet | 4 | STQC/IOTSCS/ER/021 | 22.06.2028 | IP67 (IK10 optional) | 50 m IR + 30 m warm light | RTSPS; ONVIF S/G/T | gate, night | 29.09.2026 |
| 23 | CP Plus | CP-UNC-TC41ZL6C-VMD-LQ | Bullet, motorised 2.7–13.5 mm | 4 | STQC/IOTSCS/ER/021 | 22.06.2028 | IP67 (IK10 optional) | 60 m IR + 60 m warm light | RTSPS; ONVIF S/G/T | gate, night, line | 29.09.2026 |
| 24 | CP Plus | CP-UNC-VC41L5C-VMD-LQ | Vandal dome | 4 | STQC/IOTSCS/ER/021 | 22.06.2028 | IP67, IK10 | 50 m IR + 30 m warm light | RTSPS; ONVIF S/G/T | dust, line, night | 29.09.2026 |
| 25 | CP Plus | CP-UNC-TA41L3B-D-LQ | Bullet | 4 | STQC/IOTSCS/ER/022 | 22.06.2028 | IP67 | 30 m IR + 30 m warm light | RTSPS; ONVIF S/G/T | night | 29.09.2026 |
| 26 | CP Plus | CP-UNC-DA21L3C-LQ | Dome | 2 | STQC/IOTSCS/ER/022 | 22.06.2028 | IP67 | 30 m IR + 30 m warm light | RTSPS; ONVIF S/G/T | line | 29.09.2026 |
| 27 | CP Plus | CP-UNC-WC41L3C-VMD-LQ | Dome | 4 | STQC/IOTSCS/ER/022 | 22.06.2028 | IP67, IK10 | 30 m IR + 30 m warm light | RTSP; ONVIF S/G/T | dust, line | 29.09.2026 |
| 28 | CP Plus | CP-UNC-TE81ZL6C-VMDS-Q | Bullet, motorised 2.7–13.5 mm | 8 | STQC/IOTSCS/ER/18 | 03.06.2028 | IP67 (IK10 optional) | 60 m IR | RTSPS; ONVIF S/G/T | gate, line | 29.09.2026 |
| 29 | Matrix | SATATYA CIBR20FL36CWP P2 | Bullet | 2 | STQC/IOTSCS/ER/016 | 03.03.2028 | IP67, IK10 | 50 m | RTSP; ONVIF S/G/T | night | 29.09.2026 |
| 30 | Matrix | SATATYA CIBR50FL40CWP P2 | Bullet | 5 | STQC/IOTSCS/ER/016 | 03.03.2028 | IP67, IK10 | 50 m | RTSP; ONVIF S/G/T | night, gate | 29.09.2026 |
| 31 | Matrix | SATATYA CIBR80FL36CWP P2 | Bullet | 8 | STQC/IOTSCS/ER/016 | 03.03.2028 | IP67, IK10 | 50 m | RTSP; ONVIF S/G/T | night, gate | 29.09.2026 |
| 32 | Matrix | SATATYA CIBR20MVL12CWP P2 | Bullet, motorised 2.8–12 mm | 2 | STQC/IOTSCS/ER/016 | 03.03.2028 | IP67, IK10 | 50 m | RTSP; ONVIF S/G/T | gate, night | 29.09.2026 |
| 33 | Matrix | SATATYA CIBR50MVL12CWP P2 | Bullet, motorised 2.8–12 mm | 5 | STQC/IOTSCS/ER/016 | 03.03.2028 | IP67, IK10 | 50 m | RTSP; ONVIF S/G/T | gate, night, line | 29.09.2026 |
| 34 | Matrix | SATATYA CIDR20FL28CWP P2 | Dome | 2 | STQC/IOTSCS/ER/024 | 03.03.2028 | IP67, IK10 | 50 m | RTSP; ONVIF S/G/T | dust, line, night | 29.09.2026 |
| 35 | Matrix | SATATYA CIDR50FL28CWP P2 | Dome | 5 | STQC/IOTSCS/ER/024 | 03.03.2028 | IP67, IK10 | 50 m | RTSP; ONVIF S/G/T | dust, line, night | 29.09.2026 |
| 36 | Matrix | SATATYA CIDR80FL28CWP P2 | Dome | 8 | STQC/IOTSCS/ER/024 | 03.03.2028 | IP67, IK10 | 50 m | RTSP; ONVIF S/G/T | dust, line, night | 29.09.2026 |
| 37 | Honeywell | HC50WB3R2 | Bullet, motorised (MFZ) | 3 | STQC/IoTSCS/ER/078 | 12.11.2028 | IP66/IP67, IK10 | 70 m | RTSP; ONVIF S/G/T/M | gate, night | 29.09.2026 |
| 38 | Honeywell | HC50W43R2 | Dome, motorised | 3 | STQC/IoTSCS/ER/078 | 12.11.2028 | IP66/IP67, IK10 | 50 m | RTSP; ONVIF S/G/T/M | dust, line, night | 29.09.2026 |
| 39 | Honeywell | HC50WB5R2 | Bullet, motorised 2.7–13.5 mm | 5 | STQC/IoTSCS/ER/079 | 12.11.2028 | IP66/IP67, IK10 | 70 m | RTSP; ONVIF S/G/T/M | gate, night, line | 29.09.2026 |
| 40 | Honeywell | HC50W45R2 | Dome, motorised | 5 | STQC/IoTSCS/ER/079 | 12.11.2028 | IP66/IP67, IK10 | 50 m | RTSP; ONVIF S/G/T/M | dust, line, night | 29.09.2026 |
A few things the table shows at a glance:
- Prama has the most rows because its certificates list models one by one. We read 8 of its 26 certificates.
- CP Plus "LQ" models list RTSPS (encrypted RTSP) in the datasheet protocol line. Most NVRs and video-analytics tools accept it, but ask your integrator to confirm on the recorder you already own.
- Honeywell's 50 Series lists ONVIF Profile M alongside S, G and T. Profile M carries analytics metadata, which matters if you plan to add AI later.
- Power: all rows run on standard 802.3af PoE, except the two Prama motorised bullets (PT-NC346P3 and PT-NC326P3). Their datasheets specify 802.3at (PoE+), so size your switch for them.
How we check
- Certificate first. We download every network-camera certificate PDF linked from STQC's IoTSCS Essential Requirements list: 53 certificates on 29 September 2026. We read the model table in each annexure. A model enters the table only if its exact string appears on a certificate, and we record the certificate number and the printed expiry date.
- Datasheet second. For IP rating, IR range, RTSP/ONVIF and PoE we use only the manufacturer's own product page or datasheet PDF. We don't use dealer listings, marketplace pages or reseller PDFs. For Matrix, the IP and IR figures come from the series page, which gives one spec for all fixed-lens variants in the series.
- Nothing from secondary sources. Dealer "STQC lists", including the widely copied 196-model count, only tell us where to look. If we can't confirm a row at the source, it stays out of the table.
- Monthly re-check. On the first working week of each month we re-download the STQC list for every brand in the table. We compare it against last month, re-check any certificate within six months of expiry, and update the "Checked on" date. A row that has gone more than 60 days without a check comes out of the table until it is re-checked.
What this list is not
- It is not a ranking. Rows are grouped by brand and certificate, not by quality. There are no scores and no top pick.
- It is not an image-quality test. A certificate tells you the camera passed India's cybersecurity Essential Requirements (no default passwords, encrypted streams, signed firmware and so on). It says nothing about how the picture looks in your lint-heavy weaving hall at 2 a.m.
- It is not complete. STQC holds 53 network-camera certificates covering far more models than the 40 here. We add rows only as fast as we can check them.
- It is not a reason to rip out working cameras. The certification rule applies to cameras sold, manufactured or imported from 1 April 2026. Cameras already running on your floor can stay. Our guide on whether you have to replace factory CCTV in 2026 walks through the cases. Recorders are a separate question: see do NVRs and DVRs need STQC/BIS certification.
How to verify a model yourself
It takes about five minutes per model, on two government portals:
- STQC (security, ER certificate). Go to stqc.gov.in, then IT & e-Governance → IT System & Product Certification → IoT System Certification Scheme. Press the "Archive" button under the notice to open the Essential Requirements certified product list. Open the certificate PDF for your brand and look for your exact model string, suffix included, in the annexure. Note the certificate expiry date. For cameras certified after January 2026, expect to find them on BIS CRS rather than on this list.
- BIS CRS (safety registration, R-number). Go to crsbis.in and use "Search by R-number" (the same form also searches by brand and model). Check that the status is valid and that your model is within the registration's scope. The R-number is also printed on the camera label under the BIS Standard Mark, next to "IS 13252 (Part 1)".
If the model on the installer's quote is not in either place under its exact name, ask for the certificate and the R-number in writing before you pay. Our explainer on the STQC/BIS-approved camera list covers what each stamp certifies. For picking cameras by lighting rather than by paperwork, see night and low-light cameras on a shop floor.
Changelog
- v1, 29 September 2026. First release: 40 models from 4 brands on 18 STQC ER certificates, with specs checked against manufacturer datasheets.
Sources
- STQC, IoT System Certification Scheme (IoTSCS) page, including the notice on the network-camera list (read 29.09.2026): https://www.stqc.gov.in/en/iot-system-certification-scheme-iotscs-0
- STQC, IoTSCS certified product list as per Essential Requirements, with the 53 certificate PDFs (read 29.09.2026): https://stqc.gov.in/en/iot-system-certification-scheme-iotscs-certified-product-list-essential-requirements-ers
- BIS Compulsory Registration Scheme portal: https://www.crsbis.in/
- Manufacturer datasheets: Prama product pages (pramaindia.in), CP Plus product pages and datasheet PDFs (cpplusworld.com), Matrix Project Series bullet and dome pages (matrixcomsec.com), Honeywell 50 Series datasheets (honeywell.com). Each is linked from its model name in the table.
Not sure which fits your floor? Send us a video of your floor. We'll mark where cameras should go and pick certified models from this list for each spot, or tell you which of the cameras you already have can stay.